Customer Care Telephone:  (888) 276-4666

HP Laserjet M608 50.2 Fuser Error - Step by Step Guide to Repair

HP Laserjet Printer Fuser Error

Summary

If you are up against the HP Laserjet M608 50.2 fuser error, you are not the only one. This is a normal issue for end users of the HP Laserjet M608, M609, and M607 printers. The error usually means the fuser, which is responsible for bonding the toner to the paper with heat, isn’t reaching its’ proper temperature. Without a functional fuser, your prints won’t come out as presumed, creating severe delays – especially for business or IT professionals relying on high volume printers.

In these instructions, we will guide you through what the HP Laserjet M608 50.2 fuser error is, the reason it happens, and more importantly, how to remedy it. We will go over how this problem is produced in related models, as for the HP Laserjet M607 50.2 fuser error and the HP Laserjet M609 50.2 fuser error.

HP Laserjet M608 50.2 Fuser Eror, What is?

The HP Laserjet M608 50.2 fuser error happens when the fuser assembly in the printer doesn’t attain the correct temperature in the allocated time. This can occur due to power inconsistencies, a malfunctioning fuser assembly, or even environmental factors like temperature and humidity. The fuser assembly job is to apply heat to bond the toner to paper, and it’s not working correctly, print jobs will either produce poor print quality or fail all together.

The similar error can happen with the HP Laserjet M607 50.2 fuser error and the HP Laserjet M609 50.2 fuser error. Since these HP Printer models share similar internal architecture and are subject to similar fuser issues.

General Causes of the 50.2 Fuser Error

Reasons for this error:

1. Power Supply Issues: Voltage variations or a volatile power source can make the fuser heat incorrectly.
2. Failure of the Fuser: Over time, the fuser will wear and may become damage.
3. Firmware Issues: Often times, outdated firmware can stop the printer from communicating correctly with the PCB boards and components, including the fuser assembly.
4. Environmental Conditions: Cold or humid environments can hinder the heating process of the fuser, causing a 50.2 fuser error.

How to fix the HP Laserjet M608 50.2 Fuser Error

Follow these steps to remedy the HP Laserjet M608 50.2 fuser error. These results also apply to remedying the HP Laserjet M607 50.2 fuser error, and HP Laserjet M609 50.2 fuser error.

1. Verify the Power Supply

Action: Make sure the HP Laserjet printer is plugged directly in a stable wall outlet, removing any surge suppressor or protector, which can cause voltage variations.

Reason: Power problems are one of the most frequent cause of the HP Laserjet M608 50.2 fuser error.

2. Perform Cold Rest of the HP Laserjet M608

Action: To perform a cold reset of the HP Laserjet M608 follow these steps:

A. Turn off the printer: Press the power button to turn off the printer and wait for it to completely shut down.
a) Power back on the printer:Turn the printer back on.
b) As soon as you see the HP logo on the display, immediately press the Cancel (X) button to interrupt the startup process.
c) Enter Preboot Menu:
d) The printer will enter the Preboot menu. Use the arrow keys to navigate.

B. Select Administrator:
a) In the Preboot menu, scroll down using the arrow keys and select Administrator by pressing OK.

C. Select Restore Factory Settings:
a) Scroll through the Administrator menu until you see Restore Factory Settings. Select it by pressing OK.

D. Confirm Reset:
a) The printer will ask for confirmation. Select Yes or OK to confirm.

E. Reboot the Printer:
a) The printer will perform a cold reset and restore to factory default settings. It will automatically reboot.

Once the reset is complete, the printer will return to its out-of-the-box state, removing any custom settings such as network configurations and passwords.

3. Perform Firmware Upgrade

Action: Goto hp.com and download the latest firmware for your HP Laserjet printer.

Reason: Upgrading the printer engine firmware can resolve bugs that may contribute to the HP Laserjet M608 50.2 Fuser Error or the comparable HP Laserjet M607 50.2 fuser error and the HP Laserjet M609 50.2 Fuser Error.

4. Inspect the Fuser Assembly and Reseat.

Action: Power off the printer, carefully remove the fuser, examine the fuser for visible defects and then reinstall fuser making sure the fuser snaps into place correctly.

Warning: Fusers can be very hot, Wait for it to cool down before handling.

Why: A out of align or loose fitting, fuser can cause the HP Laserjet M608 50.2 fuser error to appear. The similar problem can be seen in the HP Laserjet M607 and M609 models.

HP Laserjet M608 50.2 Fuser Error | Onsite HP Laserjet Printer Repair Promotion $59.99

5. Replace Fuser Assembly

Action: if the error continues after executing above, replace the fuser assembly.

Why: An incorrectly functioning fuser is often the main cause of the HP Laserjet M608 50.2 fuser error, as well as the same error in the HP Laserjet M607 and HP Laserjet M609 printer.

More Troubleshooting for the HP Laserjet M607, and M609

The HP Laserjet M607 50.2 fuser error and HP Laserjet M609 50.2 fuser error results in similar troubleshooting procedures as the M608 model. Then again, confirm you are using the correct voltage fuser either 120v or 220v.

If you are working with a 50.2 fuser error on HP Laserjet M607 or HP Laserjet M609, follow the same procedures listed above to remedy the fuser error issue.

HP Laserjet Printer Repair

If you attempted these remedies and the HP Laserjet M608 50.2 fuser continues to show, it may be that time to refer to a knowledgeable HP Technician. Complicated issues like a faulty DC Control or Low Voltage Power Supply (LVPS) might be outside the scope of DIY troubleshooting.

Call Printer Repair Experts at (888) 276-4666 or email us at [email protected] for expert Onsite HP Laserjet Printer Repair. We offer a flat rate promotion of $59.99 for new clients and we guarantee parts and service for 180 days (6 months).

If you are working with a 50.2 fuser error on HP Laserjet M607 or HP Laserjet M609, follow the same procedures listed above to remedy the fuser error issue.

FAQ's - Frequently Asked Questions

What does the HP LaserJet M608 50.2 fuser error mean?

The 50.2 fuser error on the HP LaserJet M608 indicates that the fuser is not reaching the required temperature in time, which prevents the toner from bonding to the paper. This could be due to power issues, a faulty fuser, or firmware problems.

How do I fix the HP LaserJet M608 50.2 fuser error?

To fix the HP LaserJet M608 50.2 fuser error, try these steps:

  1. Reset the printer.
  2. Check power connections.
  3. Update the firmware.
  4. Reseat or replace the fuser if necessary.
Can I replace the fuser myself on the HP LaserJet M608?

Yes, you can replace the fuser on your HP LaserJet M608. Just ensure you purchase the correct part (110V: RM2-1256-000CN or 220V: RM2-1257-000CN) and follow safety guidelines, as the fuser can be hot.

Articles of Interest

ONSITE HP PRINTER REPAIR

NEW CLIENT PROMOTION

$59.99

FLAT LABOR RATE

NO TRAVEL CHARGE

180 DAYS WARRANTY PARTS  &  LABOR

SCHEDULE AN APPOINTMENT  TODAY
(888) 276-4666

*Limitations apply